DESCRIPTION
Designed for attenuation and phase measurements, particularly for characterization of the attenuators built into signal sources. May be used for vector transmission measurements of two-port devices.
SPECIFICATIONS
Frequency range: 100 kHz–7.5 GHz
Attenuation measurement error (not including mismatch error):
Measured loss |
100 kHz to 17.75 GHz |
17.85 to 37.5 GHz |
to 10 dB |
≤ 0.01 dB |
≤ 0.01 dB |
to 50 dB |
≤ 0.04 dB |
≤ 0.11 dB |
to 80 dB |
≤ 0.09 dB |
≤ 0.4 dB |
to 100 dB |
≤ 0.2 dB |
≤ 1.2 dB |
to 120 dB |
≤1.1 dB |
≤ 1.6 dB |
to 140 dB |
≤ 1.2 dB |
– |
Phase measurement error (without mismatch error):
Measured loss |
100 kHz to 17.75 GHz |
17.85 to 37.5 GHz |
to 10 dB |
≤ 0.17 ° |
≤ 0.2 ° |
to 50 dB |
≤ 0.5 ° |
≤ 0.8 ° |
to 80 dB |
≤ 1 ° |
≤ 3.5 ° |
to 100 dB |
≤ 2.4 ° |
≤ 11 ° |
to 120 dB |
≤ 7 ° |
– |
Input VSWR with the matching pad of 10 dB:
≤ 1.15 (100 kHz–100 MHz);
≤ 1.25 (0.1–2 GHz);
≤ 1.3 (2–12 GHz);
≤ 1.5 (12–17.85 GHz);
≤ 2 (17.85–37.5 GHz).
GENERAL
Operating temperature range: 5–40 °C
Non-operating temperature range: – 40–50 °C
Power: 220±22 V, 50±1 Hz
Power consumption: not more than 100 VA
Dimensions: 494x506.5x257 mm
Weight: 38 kg